[. . . ] Electric Dryer PRODUCT MODEL NUMBERS WED49STB Front View 29" (737 mm) Side View 223/4" (578 mm) 273/4" (705 mm) 133/4" (349 mm) 273/4" (705 mm) 433/8" (1102 mm) /" (13 mm) 1 2 A A. [. . . ] ■■ Additional spacing of 1" (25 mm) on all sides of the dryer is recommended to reduce noise transfer. ■■ For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Closet door with vents *Required spacing W10646601A 12/2014 ELECTRICAL REQUIREMENTS To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz. , AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. Connect to an individual branch circuit. VENTING REQUIREMENTS Exhaust venting: Exhaust your dryer to the outside. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. The Vent System charts provides venting requirements that will help achieve best drying performance. Vent System Chart Number of 90° turns or elbows 0 1 2 3 4 Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box/louvered hoods 64 ft. [. . . ] For complete details, see Installation Instructions packed with product. [. . . ]